L・eye Photovoltaic power generation Lineup Comparison Chart
To the package overview pageLow voltage Line-up comparison tableAs of February 2025
Low voltage (less than 50kW) | |||||
---|---|---|---|---|---|
Plan name | Low voltage Standard | Low voltage Salt damage | Low voltage SPD | Low voltage FL | |
Measurement target | Inverter | Inverter | Inverter | Inverter | |
Storage board | Type B | Type G | Type B2 | Type A | Type F |
Communication lines | ○ | ○ | ○ | ○ | ○ |
Solar Radiation and Temperature Sensor | △ | △ | △ | △ | △ |
FLIPLINK addition | ― | △※1 | ― | △※1 | △※2 |
Low Voltage Smart Meter | △※3 | △※3 | △※3 | ― | ― |
High Voltage Smart Meter | △ | △ | △ | △ | △ |
Solar radiation diagnosis | ○※4 | ○※4 | ○※4 | ○※4 | ○※4 |
Output Ratio Diagnosis | ○ | ○ | ○ | ○ | ○ |
Aging Analysis | ○ | ○ | ○ | ○ | ○ |
Power Generation Shutdown Diagnosis | ○ | ○ | ○ | ○ | ○ |
System Diagram | ― | ― | ― | ― | ― |
Camera Image | △ | △※5 | ― | △※5 | △ |
Service provision period※6 1 year/10 years |
○ | ○ | ○ | ○ | ○ |
On-site Adjustment | △ | △ | △ | △ | △ |
Security Option | △※7 | △※7 | ― | △※7 | △ |
*1 Only FLIPLINK (for measuring solar radiation and temperature) can be added.
*2 Only one unit is free, the second unit will incur a fee.
*3 A dedicated Wi-SUN dongle is added to communicate with the low-voltage smart meter. In addition, customers must obtain an ID and password from their power company.
*4 Solar radiation and temperature measurements are required for solar radiation diagnosis.
*5 Provided in the retrofit configuration "Standard Type".
*6 The provision periods for ASP services, wireless communication services, and equipment warranties are the same as the service provision periods.
*7 Other contact measurements cannot be made with FLIPLINK DI.
High voltage Line-up comparison tableAs of February 2025
High voltage1 (50kW or more, but less than 250kW) |
High voltage2 (250kW or more, but less than 500kW) |
High voltage3 (500kW or more, but less than 1MW) |
High voltage4 (1MW or more, but less than 2MW) |
||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Plan name | High voltage1 Standard |
High voltage1 Salt damage |
High voltage1 SPD |
High voltage1 FL |
High voltage1 Power receiving and transforming |
High voltage2 Light |
High voltage2 standard |
High voltage2 standard Boxless |
High voltage2 Solar radiation and temperature |
High voltage2 Power receiving and transforming |
High voltage3 Standard |
High voltage3 Standard Boxless |
High voltage3 Power receiving and transforming |
High voltage4 Standard |
High voltage4 Standard Boxless |
High voltage4 Power receiving and transforming |
|||||
Measurement target | Inverter | Inverter | Inverter | Inverter | Inverter | Inverter・ SRTS・RTE |
Inverter | Inverter | Inverter | Inverter・ SRTS |
Inverter | Inverter・ SRTS・RTE |
Inverter | Inverter | Inverter | Inverter・ SRTS・RTE |
Inverter | Inverter | Inverter | Inverter・ SRTS・RTE |
|
Storage board | Type B | Type G | Type B2 | Type A | Type F | Type C | Type D | Type B | Type C | Type E | Type F | Type C | Type D | Type C | Type E | Type C | Type D | Type C | Type E | Type C | Type D |
Communication lines | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
Solar Radiation and Temperature Sensor | △ | △ | △ | △ | △ | △ | ○ | △ | △ | △ | ○ | △ | ○ | △ | △ | △ | ○ | △ | △ | △ | ○ |
FLIPLINK addition | ― | △※2 | ― | △※2 | △※3 | △※3 | △※4 | ― | △※2 | △※2 | △※2※3 | △※3 | △※4 | △※2 | △※2 | △※3 | △※4 | △※2 | △※2 | △※3 | △※4 |
High Voltage Smart Meter |
△ | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ |
Solar radiation diagnosis | ○※5 | ○※5 | ○※5 | ○※5 | ○※5 | ○※5 | ○ | ○※5 | ○※5 | ○※5 | ○ | ○※5 | ○ | ○※5 | ○※5 | ○※5 | ○ | ○※5 | ○※5 | ○※5 | ○ |
Output Ratio Diagnosis | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
Aging Analysis | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
Power Generation Shutdown Diagnosis | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
System Diagram | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ | △ |
Camera Image | △ | △※6 | ― | △※6 | △ | △ | △ | △ | △ | △※7 | △ | △ | △ | △ | △※7 | △ | △ | △ | △※7 | △ | △ |
Service provision period※8 1 year/10 years |
○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
On-site Adjustment | △ | △ | △ | △ | △ | ○ | ○ | △ | △ | △ | △ | ○ | ○ | △ | △ | ○ | ○ | ○ | ○ | ○ | ○ |
Security Option | △※9 | △※9 | ― | △※9 | △ | △ | △ | △※9 | △※9 | △※9※10 | △※9 | △ | △ | △※9 | △※9※10 | △ | △ | △※9 | △※9※10 | △ | △ |
*1 FLIPLINK DI, used for measuring substation equipment, supports non-voltage contacts and pulse inputs, while FLIPLINK AI supports 4-20mA/1-5V analog signals.
*2 Only FLIPLINK (for measuring solar radiation and temperature) can be added.
*3 Only one unit is free, the second unit is charged.
*4 Up to two units are free (first FLIPLINK ST), and each additional unit is charged.
*5 Solar radiation diagnosis requires solar radiation and temperature measurement.
*6 Provided in the retrofit configuration "Standard Type".
*7 If FLIPLINK is added, the retrofit configuration "Standard Type" or "Lite Type" will be provided.
*8 The provision period of ASP service, wireless communication service, and equipment warranty is the same as the service provision period.
*9 Other contact measurements cannot be made with FLIPLINK DI.
*10 If the camera image option is installed, the "Standard Type" will be provided.
Storage board list
○ Standard △ Optional (paid)power supply | Contents | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Power supply unit | AC adapter | Breaker | Terminal Blocks | UPS | OA Tap | Power SPD | RS-485 SPD / LAN SPD | HUB | FLIPLINK | |||
Type A | 100V / 200V | ○ | ― | ○ | ○ | ― | ― | ○ | ○ | ― | △ | |
Type B / B2 | 100V / 200V | ○ | ― | ― | ― | ― | ― | ― | ― | ― | ― | |
Type C | 100V | ― | ○ | ○ | ○ | ○ | ○ | ○ | ○ | △ | △ | |
Type D | 100V | ― | ○ | ○ | ○ | ○ | ○ | ○ | ○ | △ | ○ | |
Type E | 100V | ― | ○ | ○ | ○ | ○ | ○ | ○ | ○ | △ | △ | |
Type F | 100V / 200V | ○ | ― | ― | ― | ― | ― | ― | ― | ― | ○ | |
Type G | 100V | ― | ○ | ○ | ― | ― | △ | ― | ― | △ | △ |
*Please prepare a separate power supply for the HUB.
Extra High Lineup Comparison TableAs of February 2025
Extra high (2MW or more, less than 10MW) release date TBA |
Extra high (10MW or more) release date TBA |
|
---|---|---|
Plan name | Extra high10M Standard | Extra high voltage over 10M Standard |
Measurement target | Inverter・RTE・SRTS | Inverter・RTE・SRTS |
Storage board (model) |
To Be Determined | To Be Determined |
Communication lines | ○ | ○ |
Solar Radiation and Temperature Sensor | ○ | ○ |
FLIPLINK addition | △ | △ |
Solar radiation diagnosis | ○ | ○ |
Output Ratio Diagnosis | ○ | ○ |
Aging Analysis | ○ | ○ |
Power Generation Shutdown Diagnosis | ○ | ○ |
System diagram | △ | △ |
Service provision period※2 1 year/10 years |
○ | ○ |
On-site adjustment | ○ | ○ |
Security options | △ | △ |
*1 FLIPLINK DI, used when measuring substation equipment, supports non-voltage contacts and pulse inputs, while FLIPLINK AI supports 4-20mA/1-5V analog signals.
*2 The provision periods for ASP services, wireless communication services, and equipment warranties are subject to the service provision period.